Skip to main content
Denmark
Global Fin Swe Nor Den Ger Cze Svk Pol Nld Bel (nl) Bel (fr) USA
  • Aidian – Your aid in diagnostics
  • Point-of-care test
  • Produkter
  • Om os
  • QuikRead go- Instrument service
  • Indsigtshub
  • Antimikrobiel resistens
  • Messer
Kontakt os Søg
Logo
Kontakt os
  • Point of care
  • Mikrobiologi
  • Molekylær mikrobiologi
  • Hygiejneovervågning
  • RIA / Collagener
  • Hurtigtests
  • Andre
Point of care
  • QuikRead go-systemet
  • microINR
  • FACIT
  • SD BIOSENSOR STANDARD F
  • Nova Biomedical
  • Hangzhou AllTest Biotech Valofia
Læs mere
QuikRead go
  • QuikRead go Plus Instrument
  • QuikRead go Instrument
  • QuikRead go easy CRP
  • QuikRead go wrCRP+Hb
  • QuikRead go HbA1c
  • QuikRead go Strep A
  • QuikRead go iFOBT
  • QuikRead go tilbehør
QuikRead go
Mikrobiologi
  • Uricult / Uricult Trio-tests
  • Uricult Vet
  • Cultura M
  • MIKROGEN serologi
  • Meridian Immunoassays
  • Meridian Curian®
  • Reagena
Læs mere
Molekylær mikrobiologi
  • Meridian Revogene®
  • Meridian Alethia®
  • MIKROGEN molecular diagnostics
  • SD BIOSENSOR STANDARD M10
Læs mere
Hygiejneovervågning
  • Easicult
  • Hygicult
  • Cultura M
  • Clean Card PRO
Læs mere
RIA / Collagener
  • UniQ RIA
Læs mere
Hurtigtests
  • Luftvejsinfektioner
  • Mave‑tarm‑sygdomme
  • Seksuelt overførte sygdomme
  • Graviditet og fertilitet
  • Andre
Læs mere
Andre
  • Grifols Promonitor®
Læs mere
  • Aidian i Danmark
  • Bestyrelse og direktion
  • Bæredygtighed
  • Værdier og kultur
  • Karriere
  • Sundhedsemner
  • Om C-reaktivt protein (CRP)
  • Kunde historier
  • Nyheder
  • Understøttende materialer
  • Spreading of antibiotic resistant bacteria
  • Nyttige links
Modify Selected Code…
Kontakt os Tæt
  • Point-of-care test
  • Produkter
    • Point of care
      • QuikRead go-systemet
      • microINR
      • FACIT
      • SD BIOSENSOR STANDARD F
      • Nova Biomedical
      • Hangzhou AllTest Biotech Valofia
    • Mikrobiologi
      • Uricult / Uricult Trio-tests
      • Uricult Vet
      • Cultura M
      • MIKROGEN serologi
      • Meridian Immunoassays
      • Meridian Curian®
      • Reagena
    • Molekylær mikrobiologi
      • Meridian Revogene®
      • Meridian Alethia®
      • MIKROGEN molecular diagnostics
      • SD BIOSENSOR STANDARD M10
    • Hygiejneovervågning
      • Easicult
      • Hygicult
      • Cultura M
      • Clean Card PRO
    • RIA / Collagener
      • UniQ RIA
    • Hurtigtests
      • Luftvejsinfektioner
      • Mave‑tarm‑sygdomme
      • Seksuelt overførte sygdomme
      • Graviditet og fertilitet
      • Andre
    • Andre
      • Grifols Promonitor®
  • Om os
    • Aidian i Danmark
    • Bestyrelse og direktion
    • Bæredygtighed
    • Værdier og kultur
    • Karriere
  • QuikRead go- Instrument service
  • Indsigtshub
    • Sundhedsemner
    • Om C-reaktivt protein (CRP)
    • Kunde historier
    • Nyheder
  • Antimikrobiel resistens
    • Understøttende materialer
    • Spreading of antibiotic resistant bacteria
    • Nyttige links
  • Messer
Populære produkter
AllTest Valofia – vektorbårne sygdomme

AllTest Valofia – vektorbårne sygdomme

AllTest Valofia Smart- og Valofia Flow-analysatorer

AllTest Valofia Smart- og Valofia Flow-analysatorer

AllTest Valofia respiratoriske infektioner

AllTest Valofia respiratoriske infektioner

Seneste nyt
Se alt

Hurtigtests til professionel brug

4. maj 2026

New US studies strengthen the scientific evidence on CRP in lower respiratory tract infections

28. april 2026 | Nyheder, Produktnyheder

New study highlights the potential of point-of-care testing in the diagnosis of neuroborreliosis in children with peripheral facial palsy

13. april 2026 | Nyheder, Produktnyheder

  • Se alt
  • Ingen resultater fundet
  • Loading...
Nyheder

Hurtigtests til professionel brug

4. maj 2026

New US studies strengthen the scientific evidence on CRP in lower respiratory tract infections

28. april 2026 | Nyheder, Produktnyheder

Hjem Molekylær mikrobiologi SD BIOSENSOR STANDARD M10 STANDARD M10 Arbovirus Panel

STANDARD M10 Arbovirus Panel

STANDARD M10 Arbovirus Panel test is a multiplex real-time reverse transcription polymerase chain reaction (real-time RT-PCR) test intended for use with STANDARD M10 system for the qualitative detection of viral RNA from Arbovirus; Dengue virus (DENV) including 4 serotypes (Dengue virus 1~4), Zika virus (ZIKV), Chikungunya virus (CHIKV), Yellow Fever virus (YFV) and West Nile virus (WNV) in serum or plasma collected from patients with symptoms.

STANDARD M10 Arbovirus Panel
  • Generally
  • Technical data
  • About Arbovirus
  • Documents and materials

Generally

STANDARD M10 Arbovirus Panel is a molecular in vitro diagnostic assay that aids in the simultaneous detection and differentiation of DENV-1, DENV-2, DENV-3, DENV-4, ZIKV, CHIKV, YFV and WNV RNA based on nucleic acid amplification technology, real-time RT-PCR. STANDARD M10 Arbovirus Panel cartridge contains viral RNA extraction buffers and RT-PCR reagents for the in vitro qualitative detection of DENV-1, DENV-2, DENV-3, DENV-4, ZIKV, CHIKV, YFV and WNV RNA in human serum and plasma.

STANDARD M10 tests are used in combination with STANDARD M10 system consisting of a console (user interface) and one or more modules (cartridge analysis function). The system is a modular random access platform which can be easily scaled with up to 8 modules, offering a customized throughput.

Easy and simple test workflow

  • All-in-one cartridge (nucleic acid extraction and PCR amplification)
  • Minimal hands-on time, results available in 60 min
  • Intuitive touch screen user interface
  • Automated result interpretation, amplification curves provided

STANDARD M10 benefits

  • Versatile and flexible solution ― suitable for any healthcare settings
  • RT-PCR technology in one system
  • Multiplex capability, with up to 11 targets + internal control
  • Random access, scalable with up to 8 modules

Technical data

Products available

SD BIOSENSOR STANDARD M10 Arbovirus Panel Test

Use

For in vitro diagnostic use

Method

Real-time PCR amplification

Sample type

Serum and plasma

Instrument information

155067 SD BIOSENSOR STANDARD M10 CONSOLE
155068 SD BIOSENSOR STANDARD M10 MODULE

Time to result

60 minutes

Reading of the result

Automatic

Storage

Between +2 and +28 oC

Sensitivity

YFV: 100.00% (95% CI 69.15% to 100.00%)
DENV-1: 100.00% (95% CI 69.15% to 100.00%)
DENV-2: 100.00% (95% CI 54.07% to 100.00%)
DENV-3: 100.00% (95% CI 69.15% to 100.00%)
WNV: 100.00% (95% CI 2.50% to 100.00%)
ZIKV: 100.00% (95% CI 73.54% to 100.00%)
CHIKV: 80.00% (95% CI 44.39% to 97.48%)

Specificity

YFV: 98.08% (95% CI 93.23% to 99.77%)
DENV-1: 98.08% (95% CI 93.23% to 99.77%)
DENV-2: 100.00% (95% CI 96.64% to 100.00%)
DENV-3: 100.00% (95% CI 96.52% to 100.00%)
WNV: 100.00% (95% CI 96.79% to 100.00%)
ZIKV: 100.00% (95% CI 96.45% to 100.00%)
CHIKV: 100.00% (95% CI 96.52% to 100.00%)

Transportation

Between +2 and +28oC

Additionally needed

STANDARD M10 instrumentation, Blood collection tubes, Sample transfer pipettes,

Country of origin

South Korea

Registration

CE IVDD

About Arbovirus

Arboviruses are transmitted by arthropods, including those responsible for the current pandemic, flaviviruses (Dengue, Zika, Yellow Fever and West Nile, etc) and alphavirus (Chikungunya, Mayaro and Ross River, etc).These viruses are transmitted by Aedes mosquitoes, especially Aedes albopictus and Aedes aegypti are the presumed vector. The illnesses caused by arbovirus have similar clinical presentation with prominent fever, headache, rash, vomiting, fatigue, myalgias (muscle aches), arthralgias (joint aches) and other unspecific illnesses can be observed.

Dengue viruses are widely distributed throughout the tropical and subtropical areas of the world. There are four known distinct serotypes of dengue virus (DENV-1, DENV-2, DENV-3 and DENV-4). Rapid and reliable tests for primary and secondary infections of dengue are essential for patient management.

Documents and materials

SD BIOSENSOR STANDARD M10 Leaflet (EN)

Er du interesseret i et af produkterne?

  • Kontakt os

Tilmeld dig vores nyhedsbrev

Hold dig opdateret med nyheder fra Aidian og modtag indsigter fra POCT‑området

Aidian Denmark ApS

Ørestads Boulevard 73,
2300 København S


+45 8610 3020


Forespørgsler
info@aidian.dk


Salg
order@aidian.dk

Selskab
  • Om os
  • Bæredygtighed
  • Karriere
  • Kontakt os
Produkter
  • Point of care
  • Mikrobiologi
  • Molekylær mikrobiologi
  • Hygiejneovervågning
  • RIA / Collagener
  • Hurtigtests
  • Andre
Hurtige links
  • Aidian Academy
  • Indsigtshub
Copyright © 2026 Aidian
  • Data beskyttelse
  • Privatlivspolitikker
  • Cookie politik
  • Sociale medier politik