Skip to main content
Finland
Global Fin Swe Nor Den Ger Cze Svk Pol Hun Nld Bel (nl) Bel (fr) USA
  • Aidian – Your aid in diagnostics
  • Tuotteet
  • Tietoa meistä
  • Uutiset
  • Laitehuolto
  • Antibioottiresistenssi
  • Aidian Academy
  • Asiakastarinoita
  • Messut ja tapahtumat
Ota yhteyttä Hae
Logo
Ota yhteyttä
  • Vieritestaus
  • Mikrobiologia
  • Molekyylimikrobiologia
  • Hygieniavalvonta
  • RIA / kollageenit
  • Hengitystieinfektiot
  • Muut
Vieritestaus
  • QuikRead go vieritestijärjestelmä
  • QuikRead 101
  • Certest
  • Dipro LH ja Dipro hCG
  • Nova Biomedical
  • bioLytical Laboratories INSTI
  • ImmunoFLOW Mycoplasma pneumoniae
  • SD BIOSENSOR STANDARD Q
  • ACRO™ Biotech
  • microINR
  • Hangzhou AllTest Biotech
Lue lisää
QuikRead go
  • QuikRead go Plus Instrument
  • QuikRead go Instrument
  • QuikRead go easy CRP
  • QuikRead go CRP
  • QuikRead go CRP+Hb
  • QuikRead go wrCRP
  • QuikRead go wrCRP+Hb
  • QuikRead go HbA1c
  • QuikRead go iFOBT
  • QuikRead go Strep A
  • QuikRead go -tarvikkeet
QuikRead go
Mikrobiologia
  • Uricult
  • Uricult Vet
  • Cultura M
  • MIKROGEN serologia
  • Meridian Immunoassays
  • Meridian Curian®
Lue lisää
Molekyylimikrobiologia
  • ELITech Molecular Diagnostics
  • Meridian Revogene®
  • Meridian Alethia®
  • MIKROGEN molecular diagnostics
  • SD BIOSENSOR STANDARD M10
Lue lisää
Hygieniavalvonta
  • Easicult
  • Hygicult
  • Clean Card PRO
Lue lisää
RIA / kollageenit
  • UniQ
Lue lisää
Muut
  • Grifols Promonitor®
  • Dipro Druglab -huumetestit
  • Instant-View Multi Drug -huumetestit
Lue lisää
  • Historiamme
  • Hallitus ja johto
  • Aidianin kotimaan myynti
  • Vastuullisuus
  • Kulttuuri
  • Työpaikat
  • Uutiset
  • Tuoteuutiset
  • AMR
  • Tapahtumat
  • Stories from customers
  • COVID-19
  • QuikRead go Instrument -huoltolomake
  • Usein kysyttyjä kysymyksiä
  • Yhteystiedot
  • Tietoa C-reaktiivisesta proteiinista (CRP)
  • CRP alahengitystieinfektioissa
  • Lisämateriaalia
  • QuikRead go CRP -tuotteet
  • Hyödyllisiä linkkejä
  • Yleisesti
  • Tuotetiedot
  • Kurssit
  • Markkinointi- ja myyntimateriaalit
  • Usein kysytyt kysymykset
  • Unihygienia: tyynyjen ja vuodevaatteiden puhtauden seuranta
Logo
Ota yhteyttä Sulje
  • Tuotteet
    • Vieritestaus
      • QuikRead go vieritestijärjestelmä
      • QuikRead 101
      • Certest
      • Dipro LH ja Dipro hCG
      • Nova Biomedical
      • bioLytical Laboratories INSTI
      • ImmunoFLOW Mycoplasma pneumoniae
      • SD BIOSENSOR STANDARD Q
      • ACRO™ Biotech
      • microINR
      • Hangzhou AllTest Biotech
    • Mikrobiologia
      • Uricult
      • Uricult Vet
      • Cultura M
      • MIKROGEN serologia
      • Meridian Immunoassays
      • Meridian Curian®
    • Molekyylimikrobiologia
      • ELITech Molecular Diagnostics
      • Meridian Revogene®
      • Meridian Alethia®
      • MIKROGEN molecular diagnostics
      • SD BIOSENSOR STANDARD M10
    • Hygieniavalvonta
      • Easicult
      • Hygicult
      • Clean Card PRO
    • RIA / kollageenit
      • UniQ
    • Hengitystieinfektiot
    • Muut
      • Grifols Promonitor®
      • Dipro Druglab -huumetestit
      • Instant-View Multi Drug -huumetestit
  • Tietoa meistä
    • Historiamme
    • Hallitus ja johto
    • Aidianin kotimaan myynti
    • Vastuullisuus
    • Kulttuuri
    • Työpaikat
  • Uutiset
    • Uutiset
    • Tuoteuutiset
    • AMR
    • Tapahtumat
    • Stories from customers
    • COVID-19
  • Laitehuolto
    • QuikRead go Instrument -huoltolomake
    • Usein kysyttyjä kysymyksiä
    • Yhteystiedot
  • Antibioottiresistenssi
    • Tietoa C-reaktiivisesta proteiinista (CRP)
    • CRP alahengitystieinfektioissa
    • Lisämateriaalia
    • QuikRead go CRP -tuotteet
    • Hyödyllisiä linkkejä
  • Aidian Academy
    • Yleisesti
    • Tuotetiedot
    • Kurssit
    • Markkinointi- ja myyntimateriaalit
    • Usein kysytyt kysymykset
  • Asiakastarinoita
    • Unihygienia: tyynyjen ja vuodevaatteiden puhtauden seuranta
  • Messut ja tapahtumat
Suositut tuotteet
AllTest hCG pikatesti

AllTest hCG pikatesti

AllTest MONO pikatesti

AllTest MONO pikatesti

AllTest Strep A pikatesti

AllTest Strep A pikatesti

Uusimmat uutiset
Näytä kaikki

Olemme mukana Labquality Days 2025 -tapahtumassa!

22. tammikuuta 2025 | Tapahtumat

Esittelyssä QuikRead go Plus -laite!

20. tammikuuta 2025 | Uutiset, Tuoteuutiset

Increase in influenza and RSV activity in the EU/EEA

14. tammikuuta 2025 | Uutiset

  • Näytä kaikki
  • Ei tuloksia
  • Loading...
Uutiset

Olemme mukana Labquality Days 2025 -tapahtumassa!

22. tammikuuta 2025 | Tapahtumat

Esittelyssä QuikRead go Plus -laite!

20. tammikuuta 2025 | Uutiset, Tuoteuutiset

Etusivu Molekyylimikrobiologia SD BIOSENSOR STANDARD M10 STANDARD M10 MTB/NTM

STANDARD M10 MTB/NTM

STANDARD M10 MTB/NTM is a multiplex real-time PCR test intended for use with STANDARD M10 system for the qualitative detection of M. tuberculosis complex (MTBC), and non-tuberculous mycobacteria (NTM) nucleic acids in human normal sputum or sputum sediment sample.

M10 MTB NTM Cartridge
  • Generally
  • Technical data
  • About Tuberculosis (TB) and NTM
  • Documents and materials

Generally

STANDARD M10 MTB/NTM is a molecular in vitro diagnostic assay that aids in the simultaneous detection and differentiation of MTBC and NTM DNA based on nucleic acid amplification technology, real-time PCR. STANDARD M10 MTB/NTM contains bacterial DNA extraction buffers and PCR reagents for the in vitro qualitative detection of MTBC and NTM bacterial DNA in human normal sputum or sputum sediment sample.

STANDARD M10 tests are used in combination with STANDARD M10 system consisting of a console (user interface) and one or more modules (cartridge analysis function). The system is a modular random access platform which can be easily scaled with up to 8 modules, offering a customized throughput.

Easy and simple test workflow

  • All-in-one cartridge (nucleic acid extraction and PCR amplification)
  • Minimal hands-on time, results available in 72 min
  • Intuitive touch screen user interface
  • Automated result interpretation, amplification curves provided

STANDARD M10 benefits

  • Versatile and flexible solution ― suitable for any healthcare settings
  • RT-PCR technology in one system
  • Multiplex capability, with up to 11 targets + internal control
  • Random access, scalable with up to 8 modules

Technical data

Products available

SD BIOSENSOR STANDARD M10 MTB/NTM Test

Use

For in vitro diagnostic use

Method

Real-time PCR amplification

Sample type

Pretreated sputum or sputum sediment

Instrument information

155067 SD BIOSENSOR STANDARD M10 CONSOLE
155068 SD BIOSENSOR STANDARD M10 MODULE

Time to result

72 minutes

Reading of the result

Automatic

Storage

Between +2 and +28 oC

Sensitivity

100 %

Specificity

100 %

Transportation

Between +2 and +28oC

Additionally needed

STANDARD M10 instrumentation, STANDARD M10 Sputum Pretreatment Kit, Sample container, Screw capped tube, 0.067 M Phosphate/H20 buffer, Micropipette with filter tips,

Country of origin

South Korea

Registration

CE IVDD

About Tuberculosis (TB) and NTM

Tuberculosis (TB) is an infectious disease, which is caused by infection with M. tuberculosis complex organisms. It spreads to new hosts through the air from patients who have respiratory tuberculosis disease. Individuals newly infected would get symptoms from TB within weeks to months. M. tuberculosis can cause disease in almost any tissue or organ in human body, such as lungs, kidneys, nerves, and bones. Among them, pulmonary tuberculosis, the lung tissue infection, accounts for the most.

NTM refers to mycobacteria except MTBCs and M. leprae. NTM may cause lung disease, lymphadenitis, skin-soft tissue-oste infection, and disseminated diseases. Unlike M. tuberculosis, NTM, the environmental saprophytic bacteria are free living, ubiquitously present in surroundings such as soil or water. For this reason, it was thought to be harmless environmental saprophytic and only dangerous to individuals with defective lung structure or the immunosuppressed, but recently, following facts increase concern for NTM infection; number of NTM disease incidence over last two decades has been risen, long term treatment with multiple antibiotics increases antibiotic resistance, and recurrence rate is high that leads to persistent chronic infection.

In general, drug-sensitive TB can be effectively treated with a standard multi-drug administration containing first-line antibiotics and second-line antibiotics. In contrast, the NTM bacteria have significant heterogeneity in their susceptibility to standard antituberculosis drugs. Therefore, the treatment for NTM diseases should be differ from the treatment for TB, and this is the reason why identification of MTBC and NTM is required.

Documents and materials

SD BIOSENSOR STANDARD M10 Leaflet (EN)

Kiinnostuitko tuotteistamme?

  • Ota meihin yhteyttä

Aidian Oy

Koivu-Mankkaan tie 6 B,
02200 Espoo
PL 83,
02101 Espoo


Vaihde
010 309 3000


Myynti
info@aidian.fi

050 380 9684


Tilaukset
tilaukset@aidian.fi
050 381 5198

Yritys
  • Tietoa meistä
  • Vastuullisuus
  • Työpaikat
  • Ota yhteyttä
Tuotteet
  • Vieritestaus
  • Mikrobiologia
  • Molekyylimikrobiologia
  • Hygieniavalvonta
  • RIA / kollageenit
  • Hengitystieinfektiot
  • Muut
Pikalinkit
  • Aidian Academy
  • Aidian Connect
  • Laitehuolto
Copyright © 2025 Aidian
  • Tietosuojakäytäntö
  • Tietosuojaseloste
  • Evästekäytäntö
  • Sosiaalisen median käytäntö