Skip to main content
Germany
Global Fin Swe Nor Den Ger Cze Svk Pol Hun Nld Bel (nl) Bel (fr) USA
  • Aidian – Your aid in diagnostics
  • Produkte
  • Über uns
  • Nachrichten
  • Antimikrobielle Resistenz
  • Aidian Academy
  • Expertengespräche
  • Events
  • Apotheken
Kontakt Produkte bestellen Suche
Logo
Kontakt
  • Patientennahe Sofortdiagnostik (POCT)
  • Hygieneüberwachung
  • Mikrobiologie
  • Molecular Dx - microbiology
  • RIA / Kollagene
  • Atemwegsinfektionen
Patientennahe Sofortdiagnostik (POCT)
  • QuikRead go
Weiterlesen
QuikRead go
  • QuikRead go Instrument
  • QuikRead go Plus Instrument
  • QuikRead go CRP
  • QuikRead go easy CRP
  • QuikRead go CRP+Hb
  • QuikRead go wrCRP+Hb
  • QuikRead go HbA1c
  • QuikRead go Strep A
  • QuikRead go iFOBT
  • QuikRead go Zubehör
QuikRead go
Hygieneüberwachung
  • Easicult
  • Hygicult
  • Clean Card PRO
Weiterlesen
Mikrobiologie
  • Uricult Vet
  • Uricult
  • Meridian Immunoassays
  • Meridian Curian®
Weiterlesen
Molecular Dx - microbiology
  • Meridian Revogene®
  • Meridian Alethia®
Weiterlesen
RIA / Kollagene
  • UniQ
Weiterlesen
  • Aidian in Deutschland
  • Vorstand und Management
  • Unternehmenskultur
  • Nachhaltigkeit
  • Karriere
  • Nachrichten
  • Produktnachrichten
  • AMR
  • Veranstaltungen
  • Stories from customers
  • COVID-19
  • Über das C-reaktive Protein (CRP)
  • CRP und Infektionen der unteren Atemwege
  • Weiterführende Informationen
  • QuikRead go CRP-Produkte
  • Verbreitung antibiotikaresistenter Bakterien
  • Nützliche Links
  • Generally
  • Product information
  • Courses
  • Documents and materials
  • Frequently asked questions
  • CRP-Messungen bei Frühchen
  • POC-Tests im Praxisalltag
  • Schlafhygiene: Kontrolle der Sauberkeit von Kissen und Bettbezügen
  • Die Rheuma Bustour
  • POC Testungen in der Apotheke
  • Ein Plus an Service für Ihre Apotheke
  • Was ist ein CRP-Test und wie kann er Ihnen helfen?
  • Was ist ein HbA1c-Test und wie kann er Ihnen helfen?
  • Was ist ein Strep A-Test und wie kann er Ihnen helfen?
Logo
Kontakt Schließen
  • Produkte
    • Patientennahe Sofortdiagnostik (POCT)
      • QuikRead go
    • Hygieneüberwachung
      • Easicult
      • Hygicult
      • Clean Card PRO
    • Mikrobiologie
      • Uricult Vet
      • Uricult
      • Meridian Immunoassays
      • Meridian Curian®
    • Molecular Dx - microbiology
      • Meridian Revogene®
      • Meridian Alethia®
    • RIA / Kollagene
      • UniQ
    • Atemwegsinfektionen
  • Über uns
    • Aidian in Deutschland
    • Vorstand und Management
    • Unternehmenskultur
    • Nachhaltigkeit
    • Karriere
  • Nachrichten
    • Nachrichten
    • Produktnachrichten
    • AMR
    • Veranstaltungen
    • Stories from customers
    • COVID-19
  • Antimikrobielle Resistenz
    • Über das C-reaktive Protein (CRP)
    • CRP und Infektionen der unteren Atemwege
    • Weiterführende Informationen
    • QuikRead go CRP-Produkte
    • Verbreitung antibiotikaresistenter Bakterien
    • Nützliche Links
  • Aidian Academy
    • Generally
    • Product information
    • Courses
    • Documents and materials
    • Frequently asked questions
  • Expertengespräche
    • CRP-Messungen bei Frühchen
    • POC-Tests im Praxisalltag
    • Schlafhygiene: Kontrolle der Sauberkeit von Kissen und Bettbezügen
    • Die Rheuma Bustour
  • Events
  • Apotheken
    • POC Testungen in der Apotheke
    • Ein Plus an Service für Ihre Apotheke
    • Was ist ein CRP-Test und wie kann er Ihnen helfen?
    • Was ist ein HbA1c-Test und wie kann er Ihnen helfen?
    • Was ist ein Strep A-Test und wie kann er Ihnen helfen?
Beliebte Produkte
QuikRead go CRP+Hb

QuikRead go CRP+Hb

QuikRead go Plus Instrument

QuikRead go Plus Instrument

Uricult-Tests

Uricult-Tests

Neuesten Nachrichten
Alle ansehen

Sanova präsentiert den QuikRead go Plus auf dem Pädiatrischen Frühling in Seggau

15. Mai 2025 | Nachrichten, Produktnachrichten

Treffen Sie uns auf dem 32. Bayerischen Hausärztetag in Erlangen

9. Mai 2025 | Nachrichten, Veranstaltungen

Leben retten: Reinigen Sie Ihre Hände

5. Mai 2025 | Nachrichten, Produktnachrichten

  • Alle ansehen
  • keine Ergebnisse gefunden
  • Loading...
Nachrichten

Sanova präsentiert den QuikRead go Plus auf dem Pädiatrischen Frühling in Seggau

15. Mai 2025 | Nachrichten, Produktnachrichten

Treffen Sie uns auf dem 32. Bayerischen Hausärztetag in Erlangen

9. Mai 2025 | Nachrichten, Veranstaltungen

Produkte bestellen
Startseite Patientennahe Sofortdiagnostik (POCT) QuikRead go QuikRead go easy CRP

QuikRead go easy CRP

QuikRead go easy CRP ist ein zuverlässiger, schnell einfach durchzuführender Point-Of-Care Test, welches ein quantitatives CRP Ergebnis innerhalb 2 Minuten liefert. Der einzigartige one-step Sample Collector steigert die Effizienz durch die schnelle, einfache und komfortable Handhabung.

QuikRead go easy CRP Kit
  • Allgemein
  • Technische Daten
  • Kontrolle und zugehörige Produkte
  • Spezifische Eigenschaften von CRP (C-reaktives Protein)
  • Antibiotikaresistenz und CRP
  • Broschüren und Dokumente
  • Häufig gestellte Fragen
  • Videos

Allgemein

Es konnte gezeigt werden, dass quantitative CRP Bestimmungen als sensibler Indikator sowohl für eine erfolgreiche, antimikrobielle Therapie als auch für den Verlauf bakterieller Infektionen hilfreich sind. Des Weiteren ist es ein effektives Hilfsmittel bei der Überwachung und Kontrolle von postoperativen Infektionen1-5. Moderat erhöhte CRP Werte haben klinische Relevanz z.B. bei neonataler Sepsis6-8. oder systemischen Entzündungen (beispielsweise COPD9-11 und rheumatoide Arthritis11,13).

QuikRead go easy CRP bietet Ihnen

Einzigartiger one-step Sample Collector

  • Schnelle und einfache Probenahme verbessert den Arbeitsablauf
  • Angenehm für den Patienten

Lagerung bei Raumtemperatur bis zu +25°C

  • Einfache Lagerung in der Versorgungseinheit
  • Sofortige Anwendung ohne Aufwärmen der Reagenzien

Zuverlässiges CRP Ergebnis in 2 Minuten

  • Der CRP Messwertebereich für Vollblut liegt bei 1-200 mg/L und 1-120 mg/L bei Serum oder Plasma Proben

QuikRead go: POC System für einzelne oder kombinierte Parameter

  • Ein vollautomatisches Analysensystem, das mobil einsetzbar ist
  • Bi-direktionale Konnektivität – z.B. LIS/HIS Kompatibilität

Test Ergebnisse sollten immer als ein Bestandteil zu einer gesamten klinischen Evaluierung herangezogen werden.

Referenzen

  1. van Leeuwen MA & van Rijswijk MH. Acute phase proteins in the monitoring of inflammatory disorders. Baillieres Clin Rheumatol. 1994; 8 (3): 531–52.
  2. Olaison L et al. Fever C-reactive protein and other acute-phase reactants during treatment of infective endocarditis. Arch Intern Med. 1997; 157 (8): 885–92.
  3. Peltola H et al. Simplified treatment of acute staphylococcal osteomyelitis of childhood. Pediatrics.1997; 99 (6): 846–50.
  4. Philip AGS & Mills PC. Use of C-reactive protein in minimizing antibiotic exposure: Experience with infants initially admitted to a well-baby nursery. Pediatrics. 2000; 106 (1): 1–5.
  5. Pepys MB. The acute phase response and C-reactive protein. In: Warrell DA, Cox TM, Firth JD, Benz EJ, (eds). Oxford Textbook of Medicine, 4th ed. Oxford University Press, 2003; 2: 150–6.
  6. Chiesa C et al. C reactive protein and procalcitonin: Reference intervals for preterm and term newborns during the early neonatal period. Clin Chim Acta. 2011; 412 (11-12): 1053–9.
  7. Hofer N et al. Non-infectious conditions and gestational age influence C-reactive protein values in newborns during the first 3 days of life. Clin Chem Lab Med. 2011; 49 (2): 297–302.
  8. Wasunna A et al. C-reactive protein and bacterial infection in preterm infants. Eur J Pediatr.1990; 149 (6): 424−7.
  9. Pinto-Plata VM et al. C-reactive protein in patients with COPD, control smokers and nonsmokers. Thorax. 2006; 61 (1): 23–8.
  10. Mannino DM et al. Obstructive and restrictive lung disease and markers of inflammation: data from the Third National Health and Nutrition Examination. Am J Med. 2003; 114 (9): 758–62.
  11. Dahl M et al. C-reactive protein as a predictor of prognosis in chronic obstructive pulmonary disease. Am J Respir Crit Care Med. 2007; 175 (3): 250−5.
  12. Dessein PH et al. High sensitivity C-reactive protein as a disease activity marker in rheumatoid arthritis. J Rheumatol. 2004; 31 (6): 1095−7.
  13. Poole CD et al. The association between C-reactive protein and the likelihood of progression to joint replacement in people with rheumatoid arthritis: a retrospective observational study. BMC Musculoskelet Disord. 2008; 9: 146.

Technische Daten

Produkte153287 QuikRead go easy CRP, 50 Tests inkl. Sample Collector 10 µL
AnwendungIn-vitro-Diagnostikum, IVD CE
MethodeImmunturbidimetrisch
ProbentypVollblut, Serum, Plasma
Informationen zum InstrumentQuikRead go System Instrumente
Messzeit2 Minuten
Ablesen des ErgebnissesAblesen vom Instrument
Lagerung2 - 25°C
Zusätzlich erforderlich
  • QuikRead go Plus Instrument 155378
    oder QuikRead go Instrument 133893
  • QuikRead go CRP Kontrolle 153764
Ein eingetragenes WarenzeichenQuikRead go ist ein eingetragenes Warenzeichen der Aidian Oy

Kontrolle und zugehörige Produkte

Die regelmäßige Verwendung der QuikRead go CRP-Kontrolle wird empfohlen.

QuikRead CRP ist von Ringversuchen befreit (Teil B, 2.1.5 und 2.2.3 RiliBÄK). Es muss nur eine Kontrollmessung pro Woche durchgeführt werden.

Verfügbare Kontrolle:

  • 153764 QuikRead go CRP Kontrolle, mit einer Konzentration von ungefähr 25 mg/l (Bild)

Zugehörige Produkte:

  • 153211 QuikRead go Sample Collector 10µl (Bild)

Spezifische Eigenschaften von CRP (C-reaktives Protein)

  • Bei gesunden Menschen ist CRP in niedrigen Konzentrationen vorhanden; 99% haben Werte <10mg/L1 und 90% haben Werte <3 mg/L2
  • Unkomplizierte virale Infektionen führen meistens (mit wenigen Ausnahmen) zu einem leichten oder gar keinem Anstieg1
  • Bei bakteriellen Infektionen steigt die Konzentration deutlich an1
  • Erhöhte Konzentrationen sind bereits nach einem Entzündungsreiz 6 – 12 Stunden später detektierbar und erreichen ihr Maximum nach 24-48 Stunden3,4.
  • Ein Anstieg der CRP Konzentration korrespondiert zur Schwere einer Infektion1
  • Bei erfolgreicher antibiotischer Behandlung sinkt die Konzentration rapide1
  • Eine Normalisierung der Konzentration kann ein Indikator dafür sein, dass die Behandlung erfolgreich war und die Behandlung beendet werden kann1,5,6
  • Zum Großteil liegt die Konzentration bei septischen Neugeborenen unter 6 mg/L7,8,9

Referenzen

  1. Pepys MB. The acute phase response and C-reactive protein. In: Warrell DA, Cox TM, Firth JD, Benz EJ, eds. Oxford Textbook of Medicine, 4th ed. Oxford University Press, 2003. Vol 2, p.150 - 156.
  2. Shine, B., de Beer, FC., Pepys, MB. Solid phase radioimmunoassays for C-reactive protein. Clin Chim Acta, 1981,117: 13 - 23.
  3. Bjerrum L. C-reactive protein measurement in general practice may lead to lower antibiotic prescribing for sinusitis. Br J Gen Pract 2004; 54: 659 - 662.
  4. Pepys MB. C-reactive protein fifty years on. Lancet 1981; 1: 653 - 657.
  5. Philip AGS, Mills PC. Use of C-reactive Protein in Minimizing Antibiotic Exposure: Experience With Infants Initially Admitted to a Well-Baby Nursery. Pediarics 2000; 106.
  6. Ehl S et al. C-Reactive Protein Is a Useful Marker for Guiding Duration of Antibiotic Therapy in Suspected Neonatal Bacterial Infection. Pediatrics 1997; 99: 216 - 221.
  7. Hofer, N., Müller, W., Resch, B.Non-infectious conditions and gestational age influence C-reactive protein values in newborns during the first 3 days of life. Clin Chem Lab Med, 2011,49: 297 - 302.
  8. Wasunna, A., Whitelaw, A., Gallimore, R., Hawkins, PN., Pepys, MB. C-reactive protein and bacterial infection in preterm infants. Eur J Pediatr, 1990, 149: 424 - 427.
  9. Mathers, NJ., Pohlandt, F. Diagnostic audit of C-reactive protein in neonatal infection. Eur J Pediatr, 1987, 146: 147 - 151.

Antibiotikaresistenz und CRP

Antibiotikaresistenz ist eine globale Gesundheitsgefahr. CRP-Point-of-Care-Tests unterstützen die Behandlung von Atemwegsinfektionen und den Kampf gegen antimikrobielle Resistenzen.

Weiterlesen: Antimikrobielle resistenz und CRP

Broschüren und Dokumente

QuikRead go Family Brochure (DE)

When minutes matter Flyer (EN)

The Benefits of CRP Point-of-Care Testing in General Practice (DE)

Detailed Blood Sampling Instructions for QuikRead go easy CRP (DE)

QuikRead go easy CRP Brief Instructions (DE)

QuikRead go easy CRP Control Procedure Brief Instructions (DE)

QuikRead go Control Information (EN)

QuikRead go workstation Flyer (EN)

QuikRead go Technical Specifications (DE)

Bedienungsanleitungen

(For informative use only. Kindly always refer to the latest package insert in the kit.)

QuikRead go easy CRP IFU (GB, DE, FR, IT), 153287

QuikRead go easy CRP IFU (FI, SE, NO, DK), 153287

QuikRead go easy CRP IFU (NL, ES, EE, LT), 153287

QuikRead go easy CRP IFU (CZ, SK, HU, PL), 153287

QuikRead go easy CRP IFU (HR, RS, RO, GB), 153287

QuikRead go CRP Controls IFU (GB, DE, FR, ES, IT, CZ, HU, PL, SK, NL, EE, LT, SE, NO, DK, FI), 153765, 153764, 153763

Das Sicherheitsdatenblatt

Wenn Sie ein Sicherheitsdatenblatt erhalten möchten, wenden Sie sich bitte an: info@aidian.de

Häufig gestellte Fragen

Ich würde gerne das QuikRead go easy CRP Kit nutzen. Welche Gerätesoftware benötigt mein Instrument?

Sie sollten die Version 7.6.2 oder eine aktuellere Version nutzen. Diese Software Version kann auch für alle anderen Test Kits, die wir zur Verfügung stellen, genutzt werden.

Kann ich das QuikRead go easy CRP Kit auch bei Raumtemperatur lagern?

Ja, das ungeöffnete Kit kann bei Kühlschranktemperatur oder Raumtemperatur (2 … 25°C) bis zum Verfallsdatum aufbewahrt werden. Nach dem ersten Öffnen der Kit Komponenten, sind die Küvetten bei Raumtemperatur (18 … 25°C) für 3 Monate haltbar. Die Reagenzstopfen sind 6 Monate haltbar. Die Sample Collector Box kann bei 2 … 25°C bis zum Verfallsdatum aufbewahrt werden. Weitere Informationen finden Sie in der Packungsbeilage.

Warum stört der Sample Collector die Messung nicht?

Während der gesamten Messzeit, verbleibt der Sample Collector in der Küvette. Da der Sample Collector den Lichtpfad im System nicht blockiert, ist die Genauigkeit der Messung nicht davon betroffen.

Welches Probenahmesystem ist für den QuikRead go easy CRP Test geeignet?

QuikRead go Sample Collector 10 µL, die im Kit enthalten sind, müssen für die Probenahme als auch für die Kontrollmessungen genutzt werden. Diese werden dann in die QuikRead go easy CRP Küvetten überführt. Andere Probenahmesysteme oder Kapillaren sind nicht für diesen Test geeignet.

Videos

  • Testvideos mit dem QuikRead go Instrument
  • Testvideos mit dem QuikRead go Plus Instrument

Sind Sie an Produkten interessiert?

  • Bestellen
  • Kontakt

Aidian Germany GmbH

Papenreye 65
22453 Hamburg


040 5725 7760


Anfragen
info@aidian.de


Verkauf
bestellung@aidian.de

Unternehmen
  • Über uns
  • Nachhaltigkeit
  • Karriere
  • Kontakten Sie uns
  • AGBs
Produkte
  • Patientennahe Sofortdiagnostik (POCT)
  • Hygieneüberwachung
  • Mikrobiologie
  • Molecular Dx - microbiology
  • RIA / Kollagene
  • Atemwegsinfektionen
Quicklinks
  • Aidian Academy
  • Aidian Connect
  • Impressum
Copyright © 2025 Aidian
  • Datenschutz-Bestimmungen
  • Datenschutzerklärung
  • Cookie-Richtlinie
  • Social Media Policy