Skip to main content
Norway
Global Fin Swe Nor Den Ger Cze Svk Pol Hun Nld Bel (nl) Bel (fr) USA
  • Aidian – Your aid in diagnostics
  • Produkter
  • Om oss
  • Nyheter
  • Antibiotikaresistens
  • Aidian Academy
  • Messer og utstillinger
  • Kundehistorier
Kontakt oss Søke
Logo
Kontakt oss
  • Pasientnær diagnostikk
  • Mikrobiologi
  • Molekylær mikrobiologi
  • Hygiene overvåking
  • RIA / kollagen
  • Luftveisinfeksjoner
  • Andre
Pasientnær diagnostikk
  • QuikRead go-systemet
  • Certest
  • Nova Biomedical
  • microINR
  • Acro™ Biotech
  • SD BIOSENSOR STANDARD F
  • bioLytical Laboratories INSTI®
  • Hangzhou AllTest Biotech
Les mer
QuikRead go
  • QuikRead go Plus Instrument
  • QuikRead go Instrument
  • QuikRead go easy CRP
  • QuikRead go wrCRP+Hb
  • QuikRead go HbA1c
  • QuikRead go Strep A
  • QuikRead go iFOBT
  • QuikRead go tilbehør
QuikRead go
Mikrobiologi
  • Uricult
  • Uricult Vet
  • Cultura M
  • MIKROGEN serologi
  • Meridian Immunoassays
  • Meridian Curian®
  • Reagena
  • Medac EIA
Les mer
Molekylær mikrobiologi
  • Meridian Alethia®
  • Meridian Revogene®
  • MIKROGEN molecular diagnostics
  • SD BIOSENSOR STANDARD M10
Les mer
Hygiene overvåking
  • Easicult
  • Hygicult
  • Clean Card PRO
Les mer
RIA / kollagen
  • UniQ
Les mer
Andre
  • Grifols Promonitor®
  • Narkotika tester
Les mer
  • Aidian i Norge
  • Styre og ledelse
  • Bærekraft
  • Kultur
  • Karriere
  • Nyheter
  • Produktnyheter
  • AMR
  • Hendelser
  • Stories from customers
  • COVID-19
  • Om C-reaktivt protein (CRP)
  • CRP og nedre luftveisinfeksjon (NLI)
  • Undervisningsmateriell
  • QuikRead go CRP-produkter
  • Spredning av antibiotikaresistente bakterier
  • Nyttige lenker
  • Generally
  • Product information
  • Courses
  • Documents and materials
  • Frequently asked questions
  • Søvnhygiene: overvåking av renheten på puter og i sengetøy
  • Sparer både tid og stress
  • Færre feilmeldinger, raske resultater og mindre avfall!
Logo
Kontakt oss Lukk
  • Produkter
    • Pasientnær diagnostikk
      • QuikRead go-systemet
      • Certest
      • Nova Biomedical
      • microINR
      • Acro™ Biotech
      • SD BIOSENSOR STANDARD F
      • bioLytical Laboratories INSTI®
      • Hangzhou AllTest Biotech
    • Mikrobiologi
      • Uricult
      • Uricult Vet
      • Cultura M
      • MIKROGEN serologi
      • Meridian Immunoassays
      • Meridian Curian®
      • Reagena
      • Medac EIA
    • Molekylær mikrobiologi
      • Meridian Alethia®
      • Meridian Revogene®
      • MIKROGEN molecular diagnostics
      • SD BIOSENSOR STANDARD M10
    • Hygiene overvåking
      • Easicult
      • Hygicult
      • Clean Card PRO
    • RIA / kollagen
      • UniQ
    • Luftveisinfeksjoner
    • Andre
      • Grifols Promonitor®
      • Narkotika tester
  • Om oss
    • Aidian i Norge
    • Styre og ledelse
    • Bærekraft
    • Kultur
    • Karriere
  • Nyheter
    • Nyheter
    • Produktnyheter
    • AMR
    • Hendelser
    • Stories from customers
    • COVID-19
  • Antibiotikaresistens
    • Om C-reaktivt protein (CRP)
    • CRP og nedre luftveisinfeksjon (NLI)
    • Undervisningsmateriell
    • QuikRead go CRP-produkter
    • Spredning av antibiotikaresistente bakterier
    • Nyttige lenker
  • Aidian Academy
    • Generally
    • Product information
    • Courses
    • Documents and materials
    • Frequently asked questions
  • Messer og utstillinger
  • Kundehistorier
    • Søvnhygiene: overvåking av renheten på puter og i sengetøy
    • Sparer både tid og stress
    • Færre feilmeldinger, raske resultater og mindre avfall!
Populære produkter
AllTest hCG rapid test

AllTest hCG rapid test

Acro Strep A hurtigtest

Acro Strep A hurtigtest

Acro hCG hurtigtest

Acro hCG hurtigtest

Siste nytt
Se alt

Vi introduserer QuikRead go Plus Instrument!

20. januar 2025 | Nyheter, Produktnyheter

Increase in influenza and RSV activity in the EU/EEA

14. januar 2025 | Nyheter

Webinar: A Point-of-Care analyzer for DOAC testing

25. november 2024 | Hendelser

  • Se alt
  • Ingen resultater
  • Loading...
Nyheter

Vi introduserer QuikRead go Plus Instrument!

20. januar 2025 | Nyheter, Produktnyheter

Increase in influenza and RSV activity in the EU/EEA

14. januar 2025 | Nyheter

Hjem Molekylær mikrobiologi SD BIOSENSOR STANDARD M10 STANDARD M10 MDR-TB

STANDARD M10 MDR-TB

STANDARD M10 MDR-TB is a multiplex real-time PCR test intended for use with STANDARD M10 system for the qualitative detection of M. tuberculosis complex nucleic acids and drug-resistance mutation in human normal sputum or sputum sediment sample. Positive results of IS1081 and IS6110 are indicative of the presence of M. tuberculosis complex. Positive results for rpoB, katG and inhA indicate that the detected M. tuberculosis complex have drug resistance for rifampicin (RIF) and/or isoniazid (INH).

STANDARD M10 MDR TB
  • Generally
  • Technical data
  • About Tuberculosis (TB)
  • Documents and materials

Generally

STANDARD M10 MDR-TB is a molecular in vitro diagnostic assay that aids in the simultaneous detection and differentiation of IS1081 and IS6110 genes of M. tuberculosis complex strains and rpoB, katG and inhA gene as multi-drug resistant parameter based on nucleic acid amplification technology, real-time PCR. STANDARD M10 MDR-TB cartridge contains bacterial DNA extraction buffers and PCR reagents for the in vitro qualitative detection of IS1081 and IS6110 genes of M. tuberculosis complex strains and rpoB, katG and inhA gene as multi-drug resistant parameter in human normal sputum or sputum sediment specimen.

STANDARD M10 tests are used in combination with STANDARD M10 system consisting of a console (user interface) and one or more modules (cartridge analysis function). The system is a modular random access platform which can be easily scaled with up to 8 modules, offering a customized throughput.

Easy and simple test workflow

  • All-in-one cartridge (nucleic acid extraction and PCR amplification)
  • Minimal hands-on time, results available in 86 min
  • Intuitive touch screen user interface
  • Automated result interpretation, amplification curves provided

STANDARD M10 benefits

  • Versatile and flexible solution ― suitable for any healthcare settings
  • RT-PCR technology in one system
  • Multiplex capability, with up to 11 targets + internal control
  • Random access, scalable with up to 8 modules

Technical data

Products available

SD BIOSENSOR STANDARD M10 MDR-TB Test

Use

For in vitro diagnostic use

Method

Real-time PCR amplification

Sample type

Pretreated sputum or pretreated sputum sediment

Instrument information

155067 SD BIOSENSOR STANDARD M10 CONSOLE

155068 SD BIOSENSOR STANDARD M10 MODULE

Time to result

86 minutes

Reading of the result

Automatic

Storage

Between +2 and +28 oC

Sensitivity

100 %

Specificity

100 %

Transportation

Between +2 and +28oC

Additionally needed

STANDARD M10 instrumentation, STANDARD M10 Sputum Pretreatment Kit, Sample container, Screw capped tube, 0.067 M Phosphate/H20 buffer, Micropipette with filter tips,

Country of origin

South Korea

Registration

CE IVDD

About Tuberculosis (TB)

Tuberculosis (TB) is an infectious disease, which is caused by infection with M. tuberculosis complex organisms. It spreads to new hosts through the air from patients who have respiratory tuberculosis disease. Individuals newly infected would get symptoms from TB within weeks to months.

Rifampicin is a semisynthetic derivative of rifamycin B, and is widely used as the essential drug for the treatment of TB. Rifampicin binds to β-subunit of bacterial DNA dependent RNA polymerase (RNAP) and interferes with the initiation of RNA synthesis. Thus, rifampicin effectively functions as antibiotic by inhibiting essential bacterial activity. Mutation of the rpoB gene on the β-subunit causes a decrease the affinity of RNAP for rifampicin, and it causes bacteria to have resistance to rifampicin.

Isoniazid works effectively against active M. tuberculosis complex. Isoniazid is a prodrug that is activated by a strong catalase enzyme into acyl radical active form, the enzyme is named catalase-peroxidase (KatG) encoded by the katG gene. Active form of the compound disrupts the mycolic acid biosynthesis by inhibiting the NADH-dependent enoyl-acyl carrier protein reductase encoded by inhA gene. Mycolic acid is an essential building block of mycobacterial cell wall.

Mutations in the katG gene and inhA gene result in reduction or loss of isoniazid antibacterial activity by inactivation of KatG and structural changes in isoniazid compounds. In the case of multi-drug resistant tuberculosis (MDR-TB), which is resistant to rifampin and isoniazid at the same time, the effect of standard first-line treatment is not adequate. Thus, second-line anti-tuberculosis regimen is needed. For the effective treatment of tuberculosis patients, resistance tests of rifampicin and isoniazid should be performed simultaneously with the diagnosis of M. tuberculosis complex.

Documents and materials

SD BIOSENSOR STANDARD M10 Leaflet (EN)

Er du interessert i produktene?

  • Kontakt oss

Aidian Norway AS

Nydalsveien 28,
0484 Oslo


(+47) 66 78 56 30


Forespørsler
info@aidian.no


Salg
ordre@aidian.no

Selskap
  • Om oss
  • Bærekraft
  • Karriere
  • Kontakt oss
Produkter
  • Pasientnær diagnostikk
  • Mikrobiologi
  • Molekylær mikrobiologi
  • Hygiene overvåking
  • RIA / kollagen
  • Luftveisinfeksjoner
  • Andre
Hurtiglenke
  • Aidian Academy
Copyright © 2025 Aidian
  • Personvernregler
  • Personvernerklæring
  • Varsel om informasjonskapsler
  • Politikk for sosiale medier