Skip to main content
Belgium (fr)
Global Fin Swe Nor Den Ger Cze Svk Pol Hun Nld Bel (nl) Bel (fr) USA
  • Aidian – Your aid in diagnostics
  • Produits
  • À propos de nous
  • Actualités
  • RAM & CRP
  • Aidian Academy
  • Témoignages des utilisateurs
Contact Rechercher
Logo
Contact
  • Point of Care
  • Microbiologie médicale
  • Diagnostics moléculaires
  • Contrôle de l'hygiène
  • Infections des voies respiratoires
Point of Care
  • Système QuikRead go
  • SD Biosensor STANDARD F
  • VTrust
  • Uricult
En savoir plus
QuikRead go
  • QuikRead go Plus Instrument
  • QuikRead go Instrument
  • QuikRead go easy CRP
  • QuikRead go CRP
  • QuikRead go wrCRP+Hb
  • QuikRead go HbA1c
  • QuikRead go Strep A
  • QuikRead go iFOBT
  • QuikRead go accessoires
QuikRead go
Microbiologie médicale
  • Tests rapides de microbiologie
  • ELISA
  • BLOT
  • Méthodes de fluorescence
  • Antigènes en vrac
En savoir plus
Diagnostics moléculaires
  • Moleculaire POC
  • Kits PCR
En savoir plus
Contrôle de l'hygiène
  • Hygicult
  • Clean Card
En savoir plus
  • Conseil d'administration et direction
  • Développement durable
  • Fabricants
  • Culture
  • Nouvelles
  • Produit nouvelles
  • RAM
  • Événements
  • Histoires de clients
  • COVID-19
  • À propos de la protéine C-réactive (CRP)
  • Les taux CRP et les infections des voies respiratoires inférieures
  • Matériel éducatif
  • Tests QuikRead go CRP
  • Propagation de bactéries résistantes aux antibiotiques
  • Liens utiles
  • Generally
  • Product information
  • Courses
  • Documents and materials
  • Frequently asked questions
  • Hygiène du sommeil : contrôle de la propreté des oreillers et de la literie
Logo
Contact Fermer
  • Produits
    • Point of Care
      • Système QuikRead go
      • SD Biosensor STANDARD F
      • VTrust
      • Uricult
    • Microbiologie médicale
      • Tests rapides de microbiologie
      • ELISA
      • BLOT
      • Méthodes de fluorescence
      • Antigènes en vrac
    • Diagnostics moléculaires
      • Moleculaire POC
      • Kits PCR
    • Contrôle de l'hygiène
      • Hygicult
      • Clean Card
    • Infections des voies respiratoires
  • À propos de nous
    • Conseil d'administration et direction
    • Développement durable
    • Fabricants
    • Culture
  • Actualités
    • Nouvelles
    • Produit nouvelles
    • RAM
    • Événements
    • Histoires de clients
    • COVID-19
  • RAM & CRP
    • À propos de la protéine C-réactive (CRP)
    • Les taux CRP et les infections des voies respiratoires inférieures
    • Matériel éducatif
    • Tests QuikRead go CRP
    • Propagation de bactéries résistantes aux antibiotiques
    • Liens utiles
  • Aidian Academy
    • Generally
    • Product information
    • Courses
    • Documents and materials
    • Frequently asked questions
  • Témoignages des utilisateurs
    • Hygiène du sommeil : contrôle de la propreté des oreillers et de la literie
Produits populaires
QuikRead go Plus Instrument

QuikRead go Plus Instrument

SD Biosensor STANDARD F pathogènes gastro-intestinaux

SD Biosensor STANDARD F pathogènes gastro-intestinaux

SD Biosensor STANDARD F pathogènes respiratoires

SD Biosensor STANDARD F pathogènes respiratoires

Dernières nouvelles
Tout voir

Découvrez l'instrument QuikRead go Plus!

12 novembre 2024 | Nouvelles, Produit nouvelles

Meet us at the ECCI Conference 2024!

24 septembre 2024 | Événements

Early Strep A diagnosis can ensure prompt treatment and minimal spread of the infection

28 février 2024 | Nouvelles, Produit nouvelles

  • Tout voir
  • Aucun résultat trouvé
  • Loading...
Nouvelles

Découvrez l'instrument QuikRead go Plus!

12 novembre 2024 | Nouvelles, Produit nouvelles

Meet us at the ECCI Conference 2024!

24 septembre 2024 | Événements

Homepage Diagnostics moléculaires Moleculaire POC SD Biosensor STANDARD M10

SD Biosensor STANDARD M10

STANDARD M10 is an automated point of care MDx system. STANDARD M10 is a random access and scalable solution that enables simple, fast and accurate molecular diagnostic of infectious disease, drug resistance and genetic testing from human specimen.

SD Biosensor Standard M 700x500px
  • General information
  • Technical information
  • Available tests
  • Marketing materials

General information

STANDARD M10 can be used for both qualitative and quantitative measurement of biomarkers from human samples, such as blood, urine, and nasal mucus in a laboratory or POCT environment. The system automatically extracts and amplifies nucleic acids (DNA and RNA) for molecular diagnostics and analyzes the data from amplification in real time.

STANDARD M10 consists of STANDARD M10 console (user interface), STANDARD M10 module (cartridge analysis function), and ready-to-use kits. STANDARD M10 is modular and scalable system, with customized throughput. One console can be connected to 1-8 modules. Each module can be used individually, enabling random access testing of patient samples.

Easy and simple workflow

  • All-in-one cartridge (nucleic acid extraction and amplification)
  • Intuitive and simple touch screen user interface
  • Fast and reliable results in 20-60 minutes
  • Minimal hands-on time (less than 3 minutes)
  • Automated result interpretation, amplification curves provided

Versatile and flexible solution ― suitable for any healthcare settings

  • RT-PCR and isothermal amplification (LAMP) technology in one system
  • Multiplex capability, with up to 11 targets + internal control
  • Random access, with a scalable configuration, up to 8 modules

Technical information

Products available
  • SD-11M1011 SD BIOSENSOR STANDARD M10 CONSOLE
  • SD-11M1012 SD BIOSENSOR STANDARD M10 MODULE
UseFor in vitro diagnostic use
Method

Molecular, real-time PCR and isothermal amplification

Sample typeAnalyte dependent
Time to result
Analyte dependent, 20-60 min
Reading of the result
Automatic
Storage
Between +15 and +35 °C, humidity 20-80%
Sensitivity
Analyte dependent
Specificity
Analyte dependent

Transportation

Between -20 and +50 °C
Size and weight
  • M10 Console : 17x23x39cm, 2 kg
  • M10 Module: 14x33x32 cm, 7 kg
Additionally needed
Assay specific test kits
Country of origin
South Korea
Registration
CE IVD

Available tests

  • SD-11COV10A STANDARD M10 SARS-CoV-2
  • SD-11FLU10A STANDARD M10 FLU/RSV/SARS-CoV-2
  • SD-11MTB10A STANDARD M10 MDR-TB
  • SD-11MTB20A STANDARD M10 NTM-TB
  • SD-11CDC10A STANDARD M10 C. difficile

Marketing materials

SD BIOSENSOR STANDARD M10 Leaflet (EN)

SD-11COV10A STANDARD M10 SARS-CoV-2
SD-11FLU10A STANDARD M10 FLU/RSV/SARS-CoV-2
SD-11MTB10A STANDARD M10 MDR-TB
SD-11CDC10A STANDARD M10 C. difficile

Video

Pour plus d'informations ou un premier entretien ?

  • Nous contacter

Kies uw taal / Choisissez votre langue

Français
Nederlands

Aidian Belgium BV

Pegasuslaan 5,
1831 Diegem


+31 (0)317 35 18 38


Demandes
info@aidian.be


Ventes
cs@aidian.be

Société
  • À propos de nous
  • Développement durable
  • Contact
Produits
  • Point of Care
  • Microbiologie médicale
  • Diagnostics moléculaires
  • Contrôle de l'hygiène
  • Infections des voies respiratoires
Liens rapides
  • Aidian Academy
  • Aidian Connect
Copyright © 2025 Aidian
  • Déclaration de confidentialité
  • Note d'information
  • Politique en matière de cookies
  • Politique relative aux réseaux sociaux